KOŁAKOWSKI T.E.
50 Years of the Polish Power System
Energetyka 2001, No. 3, p. 107 KASPRZYK S., DUDZIK J. RADZIO I.
Fifty Anniversary of Dispatcher Services
Energetyka 2001, No. 3, p. 109
ŚLIMAK K.
Yesterday and Today of Operation in Northern Area of the National Power System
Energetyka 2001, No. 3, p. 113, figs 3, tab. 1
WOLAK J.
History and Activity of Dispatcher Services in Southeast Area of the Country
Energetyka 2001, No. 3, p. 116
SENGER J.
50 Years of the Area Dispatcher Service in Eastern Part of the National Power System
Energetyka 2001, No. 3, p. 118, figs 1
OZIEMBLEWSKI K.
50 Years of Dispatcher Services in South Area of the National Power System
Energetyka 2001, No. 3, p. 120, figs 5
PRZYGODA S., MAGDA A.
IT REE. A Data Communication Infrastructure within the Electric Energy Market
Energetyka 2001, No. 3, p. 123
SOBOTA J
Proposition of Modification Way for Establishing Boiler Gross Efficiency with the Indirect Method According to the Polish Standard PN-72/M-34128
Energetyka 2001, No. 3, p. 125
(ZPBE Energopomiar Bulletin, p. 1), 2 figs, 1 tab., 8 refs.
Presented is proposition for supplementing and modification of establishing procedures for boiler efficiency with indirect method according to the standard being in force. Presented procedures enable to establish the efficiency with considerable greater accuracy than one given in this standard. The proposition can be used at eventual standard updating.
HABRYKA A.
Operation Conditions of Boiler Waterwalls when Vortex Low Emission Burning of the Coal Dust is Used
Energetyka 2001, No. 3, p. 133
(ZPBE Energopomiar Bulletin, p. 9), 4 figs, 6 refs
Presented is a Technology of vortex low emission burning of the coal dust in boilers, test scope and methodology used in the case of boilers utilised this technology and remarks concerning conditions of waterwall operation in these boilers.
BIELIKOWSKI W.
Corrosion of Boiler Heating Surfaces under Low Emission Burning
Energetyka 2001, No. 3, p. 136
(ZPBE Energopomiar Bulletin, p. 12), 9 figs, 2 tabs, 10 refs
Discussed are reasons of corrosion of waterwall and superheater tubes at a low emission burning.
KOCHEL Z., RODOŃ F.
PB - An Interlocking Relay for Earthing Connector
Energetyka 2001, No. 3, p. 144
(ZPBE Energopomiar Bulletin, p. 20), 2 figs
GŁOWOCZ R.
System for the Monitoring and Localisation of Earthings in Isolated DC Current Grids
Energetyka 2001, No. 3, p. 146
(ZPBE Energopomiar Bulletin, p. 22), 3 figs
BICKI Z., SOLIŃSKI J.
Proceedings of the Assembly of the World Energy Council in New Delhi
Energetyka 2001, No. 3, p. 149